Dataset - Dissolved Al in the Southern Ocean
Summary
Sampling and Analytical Methodology: Samples were taken using 24 internally Teflon-coated PVC 12 litre GO-FLO Samplers (General Oceanics Inc.) mounted on an all-titanium frame (De Baar et al., 2008). This frame was connected to a 17.7 mm diameter Kevlar hydrowire with seven independent internal signal/conductor cables (Cousin Trestec S.A.) and controlled from onboard. Each GO-FLO sampler had a special ultraclean all-teflon PTFE valve (Cole Parmer; PN A-06392-31) installed. Samples for trace metal analysis were collected from the GO-FLO bottles in a class 100 clean room environment. The water was filtered over a 0.2 μm filter cartridge (Sartrobran-300, Sartorius) under pressure (1.5 atm) of (in-line prefiltered) nitrogen gas exerted via a special connector instead of the regular air bleeding valve at the top of each GO-FLO sampler. Sub-samples for Al were taken in cleaned LDPE sample bottles (125 mL) from each GO-FLO bottle. All sample bottles were rinsed five times with the sample seawater. The analyses of dissolved Al were performed on shipboard after the method developed by Resing and Measures (1994) with improvements by Brown and Bruland (2008). This method is a flow injection analysis, based on the fluorescence from the reaction between lumogallion and Al. Samples were stored in a refrigerator (4°C) and analysed usually within 24 h after sampling but always within 36 h. Samples were acidified at least 1 h before analysis with 12 M ultraclean HCl (Baseline® Hydrochloric Acid, Seastar Chemicals Inc.) to a pH of 1.8. In the flow injection system the samples were buffered inline to a pH of 5.5 ± 0.1 with ultraclean 2 M ammonium acetate buffer. This buffer was produced after Aguilar-Islas et al. (2006) by diluting a saturated solution of ammonium acetate crystals to a 2 M solution with MQ (Millipore Milli-Q deionised water R > 18.2 MΩ cm-1). The pH was subsequently adjusted to be between 8.8 and 8.9 with ultraclean ammonium hydroxide. The latter was produced by bubbling 0.2 µm filtered high purity ammonia gas through MQ water. The buffered sample was pre-concentrated during 200 s on a Toyopearl AF-Chelate 650M (TosoHaas, Germany) column. Hereafter the column was rinsed for 60 s with MQ water to remove interfering salts. The Al was subsequently eluted from the column with 0.16 M HCl (Suprapure, Merck) during 250 s. The eluate of Al in HCl entered the reaction stream which consisted of a lumogallion (Pfaltz & Bauer) solution in 4 M ammonium acetate buffer. The 4 M buffer was produced similar to the 2 M buffer (see above), but with the pH adjusted to be between 6.4 and 6.5 and the lumogallion was a 4.8 mM solution in MQ. The mixing of the HCl and the buffer results in a reaction pH between 5.3 and 5.4 at which an Al-Lumogallion chelate complex is formed which can be detected by its fluorescence. The complex was mixed in a 10 m reaction coil placed in a water bath of 50 °C. Hereafter a 5% Brij-35 (Merck) solution in MQ was added to increase the sensitivity (Resing and Measures, 1994) and mixed in a 3 m length mixing coil. Afterwards the emission of the fluorescent complex was detected on a FIA-lab PMT-FL detector with a 510 until 580 nm emission filter and a 480 until 490 nm excitation filter. Concentrations of Al were calculated in nanomol•L-1 (nM) from the peak heights. The system was calibrated using standard additions from a 5000 nM Al stock solution (Fluka) to filtered acidified seawater of low (<0.5 nM) Al concentration that was collected in the Antarctic Ocean. A six-point calibration line (0, 1, 2, 4, 6 and 8 nM Al standard additions) and blank determination were made every day. The 3 lowest points (0, 1 and 2 nM Al standard additions) of the calibration line were measured in triplicate and the 3 highest points (4, 6 and 8 nM Al standard additions) in duplicate in order to add more weight to the lower part of the calibration line. The blank was determined by plotting the signals of increasing pre-concentration times (30, 60, 120, 180 and 240 seconds) of the filtered acidified seawater of low (<0.5 nM) Al concentration also used for the calibration. A line was fitted through these data points and the intercept of the line taken as the blank, which was usually below 0.2 nM Al. The latter value of 0.2 nM was also the maximum allowed blank before starting a series of analyses. The limit of detection, defined as three times the standard deviation of the lowest concentration observed, was 0.07 nM. The flow injection system was cleaned every day by rinsing with a 0.5 M HCl solution. Data Processing: A standard was measured in triplicate every day. This standard was a sub-sample of a 25 L volume of filtered seawater that was taken at the beginning of the cruise in the South East Atlantic Ocean. The relative standard deviation of the replicate analysis seawater sample that was analysed 36 times on different days in triplicate was 3.16%. The relative standard deviation on single days was on average 1.5%. The average concentration of Al of this standard was 3.56 nM and the deviation from this average for a given measuring day was used as a correction factor. To verify whether this correction was decreasing the inter-daily variability in the dataset, every day a sample which was collected and measured the previous measuring day, was analysed once again. The deviation between the concentrations measured on the different days decreased from 4.8% to 3.5%, indicating the data correction is beneficial. As an independent comparison, the certification samples collected on the American SAFe cruise (Johnson et al., 2007) were analysed in triplicate for Al. The resulting concentrations of Al for both SAFe Surface (S) and SAFe deep (D2) from 1000 m, agreed very nicely the community consensus value on the absolute concentrations of Mn in the SAFe samples. The dataset was scanned for obvious outliers and these have been quality flagged with the number 4. Some samples gave anomalous nutrient results for the intended depth and were assumed to have been closed at the wrong depth and quality flagged with the number 8. All other values are assumed to be correct and flagged with the number 0.
Originating center
Royal Netherlands Institute for Sea Research (NIOZ)
Participants
Dataset progress
in work
Data quality
Data Processing: A standard was measured in triplicate every day. This standard was a sub-sample of a 25 L volume of filtered seawater that was taken at the beginning of the cruise in the South East Atlantic Ocean. The relative standard deviation of the replicate analysis seawater sample that was analysed 36 times on different days in triplicate was 3.16%. The relative standard deviation on single days was on average 1.5%. The average concentration of Al of this standard was 3.56 nM and the deviation from this average for a given measuring day was used as a correction factor. To verify whether this correction was decreasing the inter-daily variability in the dataset, every day a sample which was collected and measured the previous measuring day, was analysed once again. The deviation between the concentrations measured on the different days decreased from 4.8% to 3.5%, indicating the data correction is beneficial. As an independent comparison, the certification samples collected on the American SAFe cruise (Johnson et al., 2007) were analysed in triplicate for Al. The resulting concentrations of Al for both SAFe Surface (S) and SAFe deep (D2) from 1000 m, agreed very nicely the community consensus value on the absolute concentrations of Mn in the SAFe samples. The dataset was scanned for obvious outliers and these have been quality flagged with the number 4. Some samples gave anomalous nutrient results for the intended depth and were assumed to have been closed at the wrong depth and quality flagged with the number 8. All other values are assumed to be correct and flagged with the number 0.
Access constraints
No constraints
Use constraints
Please contact Rob Middag at NIOZ for citation details.
Projects
Publications
Middag, R., de Baar, H.J.W., et al., 2013. Fluxes of dissolved aluminum and manganese to the Weddell Sea and indications for manganese co-limitation. Limnol. Oceanogr 58 (1), 287-300
Middag, R., de Baar, H.J.W., et al., 2012. The effects of continental margins and water mass circulation on the distribution of dissolved aluminum and manganese in Drake Passage. Journal of Geophysical Research: Oceans 117 (c1)
Middag, R., van Slooten, C., et al., 2011. Dissolved aluminium in the Southern Ocean. Deep Sea Research Part II: Topical Studies in Oceanography 58 (25), 2647-2660
de Baar, H.J.W., Timmermans, K.R., et al., 2008. Titan: A new facility for ultraclean sampling of trace elements and isotopes in the deep oceans in the international Geotraces program. Elsevier 111 (1), 4-21
Brown, M.T. & Bruland, K., 2008. An improved flow-injection analysis method for the determination of dissolved aluminum in seawater. Limnol. Oceanogr. Methods 6, 87-95
Johnson, K.S., Elrod, V., et al., 2007. Developing standards for dissolved iron in seawater. Eos, Transactions American Geophysical Union 88 (11), 131-132
Resing, J.A. & Measures, C., 1994. Fluorimetric determination of Al in seawater by flow-injection with in-line preconcentration. Analytical Chemistry 66 (22), 4105-4111
Links
No linksStart date
2008-02-11
End date
2008-04-13
Region
Antarctica
Location
- Ocean > Atlantic Ocean > South Atlantic Ocean
- Ocean > Southern Ocean
- Ocean > Southern Ocean > Prime Meridian
- Geographic Region > Polar
- Ocean > Southern Ocean > Weddell Sea
ISO topic
- Environment
- Geoscientific Information
- Oceans
Science keywords
- Oceans > Ocean Chemistry > Trace Elements
Ancillary keywords
- Aluminum
- GEOTRACES
- IPY-NL